Bis(3-methoxybutyl) peroxydicarbonate
Trade name: Initiators MOBPC
English name: Di(3-methoxybutyl)peroxydicarbonate
Chemical name: Bis(3-methoxybutyl) peroxydicarbonate
Chemical structural formula:
Molecular formula: C12H22O8? ? ? ?
Molecular weight: 294.3
Theoretical active oxygen content: 5.44%
CAS No. : 52238-68-3
UN No. 3115
Einecs : 257-773-4?
Security indicators:
Half-life (measured in chlorobenzene solution):
0.1 hours: 72°C
1 hour: 57°C
10 hours: 43°C
Thermal stability data:
Self-accelerated decomposition temperature (SADT): 10°C
Critical Temperature (Tem): 0°C
Control temperature (Tc): -10°C
Storage temperature (Tsmax/TSmin): -10/-20 °C
Activation energy E (KJ/mol): 143.29
Technical standards:
Appearance: clarified liquid
Content: 49.0-51.0%
Inorganic and organic hydrolyzable chlorine: 500 mg/kg max.
Safety Precautions.
1. Keep away from fire, open flames and heat sources.
2. Avoid exposure to reducing agents (e.g., amines), acids, alkalis and heavy metal compounds (e.g., accelerants, metal soaps, etc.)
3. Refer to the Safety Data Sheet (MSDS) for this product.
Uses:
Initiator for the polymerization and copolymerization of ethylene, vinyl chloride, vinylidene chloride, acrylates and methacrylic acid.
Storage conditions:
Keep the package airtight and in a well ventilated state, the maximum storage temperature is -10 ℃, avoid and reducing agents such as amines, acids, alkalis, heavy metal compounds (accelerators and metal soaps), is strictly prohibited in the storage room to split and take.
Storage stability:
Stored in accordance with the conditions prompted by the manufacturer, the product can be guaranteed to meet factory technical standards within three months.
Fire Fighting:
Small fires need to be extinguished with dry powder or carbon dioxide extinguishers and sprayed with large amounts of water to prevent re-ignition. Large fires need to be sprayed with large quantities of water from a safe distance away.